No products in the Quote.
Home Our Equipment Water Quality Monitors Conductivity and TDS meter
The ORAKEL range of Conductivity meters also double as a Salinity meter and a TDS meter. The range measures conductivity in water from 0 to 2,000,000 µS/cm (range selectable). You can choose between a standard graphite sensor and a more sophisticated toroidal sensor, or stainless steel ‘special’ sensors for high temperature, high pressure conductivity measurement applications.
When connected with the ORAKEL controller it turns into one of the best water conductivity meters on the market suitable for the the online conductivity measurement of any liquid. Through the ORAKEL controller you get a variety of communication protocols, on screen display and many control options. Working as a TDS meter, the ORAKEL indicates the Total Dissolved Solids (TDS) of a solution and provides the readings on the display screen.
Electrodes encourage microorganisms to grow on the surface of the probe before they would grow on the surfaces of a pipe or a vessel. The biological activity of the biofilm creates a signal. The controller collects and monitors that signal continually. An increasing trend in the signal indicates the onset of biofilm activity on the probe.
The controller can then take remedial action automatically by, for example, increasing or decreasing the biocide levels, triggering email or text alarms and data logging.
Total Dissolved Solids (TDS) and salinity are both measured with conductivity sensors, and the ORAKEL controllers can provide outputs and on screen displays of calculated TDS and salinity readings from the conductivity sensors. ORAKEL controllers come with standard user adjustable, factors for calculating TDS and salinity.
Graphite
Our light industrial conductivity sensor utilises Graphite technology. The durable epoxy body construction provides a rugged and dependable sensor for potable water and clean water. Mount them in-line, in a pipe “T” fitting, or submerse them into a tank. For many applications, the epoxy body conductivity sensors are the lowest cost, most reliable conductivity sensor to use, especially for process applications. Rugged epoxy bodies make the sensors virtually unbreakable. These are an excellent choice to use as standard online conductivity electrodes in the water and related industries.
Toroidal
The toroidal inductive conductivity sensors feature a wide measurement range and dependable toroidal technology over the range 0-2,000,000 µS/cm. Resistant to corrosion, coatings and fouling common to contacting conductivity sensors, this probe is designed for a trouble free and long service life. Noryl is the standard material of construction and has a wide solvent tolerance and temperature stability to 105ºC. All models can be submersed by utilising the 3/4” MNPT threads on the sensor or installed in 2” NPT tees for in-line deployment. A temperature sensor is built into the conductivity sensor for automatic temperature compensation.
GRAPHITE
SPECIALS
TOROIDAL
All of our conductivity sensors can be used to measure salinity and TDS (Total Dissolved Solids).
Particle counters are known for their ability to detect when a filter is reaching the end of its life. ORAKEL Particle Counters are sophisticated instruments suitable for municipal and industrial water treatment applications including filter performance monitoring, protecting RO membranes from colloidal fouling and corrosion product monitoring.
The ORAKEL range of Residual Chlorine Analysers, Residual Chlorine Controllers and Residual Chlorine Monitors are membrane devices which are insensitive to changing pH, use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs.
The membraned amperometric chlorine sensors are enhanced with a third, reference electrode which eliminates zero drift. Its unique design means that pH correction is not usually required at all, completely eliminating reagents.
The ORAKEL Suspended Solids senor has a large dynamic range, which eliminates the need for a “zero” and also eliminates the effect of background light.
For multiple measuring ranges, the suspended solids sensor can monitor turbidity and suspended solids from 2 NTU (1mg/l) to 8%* solids.
The ORAKEL peracetic acid sensor is a membrane device which use no reagents. It is extremely stable and has a reduced maintenance and reduced whole life costs.
With its reduced maintenance, reduced calibration and reduced spares requirements, the ORAKEL peracetic acid sensor is arguably the most cost effective peracetic acid analyser available.
The ORAKEL COD/TOC Sensor uses UV254 light as a surrogate measurement for detecting organics in water.
It is designed in modular form so that it can be integrated with other sensors, such as pH, turbidity and dissolved oxygen, to provide all the tools needed for either a stand-alone UV254 analyser or as part of an effluent discharge monitoring system.
The ORAKEL COD/TOC Sensor provides online continuous organics monitoring utilising a 254nm ultraviolet light source.
Optical luminescent devices which are extremely resistant to abrasion, extremely stable, and have greatly reduced maintenance and whole life costs.
The ORAKEL Dissolved Oxygen sensor has no chemicals or moving parts. It is stable and reliable making it excellent for process controls and is suitable for all Dissolved Ovygen applications.